gigasept® pearls

Active oxygen-based instrument disinfectant for manual cleaning and disinfection with a multi-enzyme formula

Our Plus

  • full microbiological effectiveness via its synergistic combination of active substances plus active oxygen (concluding virucidal disinfection with 2% in 10 minutes)
  • outstanding cleaning performance via its multi-enzyme formula (protease, lipase and amylase) in combination with a neutral pH (non-protein-fixing) and powerful surfactants
  • excellent material compatibility even with sensitive materials such as flexible endoscopes
  • more user safety - thanks to its the innovative pearl structure - dust-free (no risk of inhalation)
  • innovative packaging system for safe and easy removal
  • surprisingly pleasant smell

Downloads

Fields of Application

Universal cleaning and disinfection of thermostable and thermolabile medical instruments of all types. Particularly suitable for flexible endoscopes and sensitive materials such as silicone, polycarbonate, polysulfone and acrylic glass. Furthermore, its special formulation is suitable for use in an ultrasonic bath, as well as manual reprocessing and circulation procedures (semi-automatic).

Instructions for use

The instrument disinfection granules are diluted with cold water to the desired concentration for use. 

Dosage: 1.0 % - 2.0 %, depending on microbiological activity. Prepare the solution with the enclosed measuring spoon. 

Example for use: 10 litres of a 2 % working solution is equivalent to 9.8 litres of water and 200 g gigasept® pearls. Add water and sprinkle in the appropriate amount of granules. Stir several times for the first 15 minutes. After this activation time, the working solution is ready for use. Minor undissolved residues form an active deposit of activity, but do not impair the effectiveness of the solution. Immediately after use, immerse endoscopes and instruments to be reprocessed into the working solution. Ensure complete coverage, including hollow instruments, and allow to act. After instrument reprocessing, rinse/flush thoroughly with water of at least drinking water quality, preferably deionised water, in order to completely remove residues of the disinfectant solution. Please refer to the reprocessing recommendations by the instrument manufacturer. Do not mix with other cleaning products or disinfectants.
National regulations may require that cleaning and disinfection are carried out in two separate process steps.
Standing time: Replace working solutions every working day and if contamination is clearly visible.

Microbiological efficacy

EfficacyConcentrationContact time
bactericidal, levurocidal
EN13727, EN14561, EN13624, EN14562
- dirty conditions
2%5 min.
bactericidal, levurocidal
EN13727, EN14561, EN13624, EN14562
- dirty conditions
1%10 min.
tuberculocidal
in accordance with VAH
- dirty conditions
2%5 min.
tuberculocidal
in accordance with VAH
- dirty conditions
1%15 min.
tuberculocidal
EN14348, EN14563
- dirty conditions
2%5 min.
tuberculocidal
EN14348, EN14563
- dirty conditions
1%10 min.
virucidal
in accordance with DVV
- dirty conditions
2%10 min.
virucidal
in accordance with DVV
- dirty conditions
1%30 min.
virucidal
EN14476
- dirty conditions
2%10 min.
virucidal
EN14476
- dirty conditions
1%60 min.
sporicidal (Bacillus subtillis)
EN13704
- dirty conditions
2%15 min.
sporicidal (Bacillus subtillis)
EN13704
- dirty conditions
1%30 min.
sporicidal (Clostridium difficile)
EN13704
- dirty conditions
2%5 min.
sporicidal (Clostridium difficile)
EN13704
- dirty conditions
1%30 min.
fungicidal
EN13624
- dirty conditions
2%30 min.
fungicidal
EN13624
- clean conditions
2%15 min.
fungicidal
EN13624
- clean conditions
1%60 min.

Product data

Composition:
100 g of the granules contains the following active ingredients: 43.0 g Sodium percarbonate, 22.0 g Tetraacetylethylenediamine.

Labelling according to Regulation (EC) No 648/2004:
> 30 % oxygen-based bleaching agents, < 5 % non-ionic surfactants,
< 5 % phosphates, < 5 % EDTA and salts thereof, enzymes, perfumes.

Special advice

Always read the label and product information before use.
Not suitable for instruments made of brass and copper, or chrome- or nickel-plated instruments that have been mechanicallypre-damaged.
The efficacy can be checked using indicator strips (Article code:70000746), e.g. for contaminated solution or elevated temperature.
With the addition of specific adjuvants, the pH of gigasept® pearls is buffered within a neutral range. This prevents protein coagulation (binding of proteins on surfaces) and also provides optimal material compatibility.
Carryover of small amounts of application solution from the precleaning is not expected to involve interactions with cleaning agents and disinfection agents from automated endoscope reprocessing (e.g. glutaraldehyde and peracetic acid base).

Information for order

ItemDelivery formItem no.
gigasept® pearls 1.5 kg4/Carton70000179


Environmental information

 schülke manufactures products economically and with advanced, safe and environmentally friendly production processes while at the same time maintaining out high quality standards.

CE 0297

Privacy Policy

We use analysis methods (e. g. cookies) to measure how often our site is visited and how it is used.
We embed third-party content from other providers (e. g. videos) on our site. We have no influence on further data processing and any tracking by the third party provider.
In this context, we also use service providers in third countries outside the EU that do not have an adequate level of data protection, which harbors the following risks: Access by authorities without informing the data subject, no data subject rights, no legal remedies, loss of control.
With your settings you consent to the processes described above. You can revoke your consent with effect for the future. You can find more information in our privacy policy.